Autoshift 3 Hub: Cog Installation

  • Slide the steel spacer onto the freehub with the chamfered side facing inboard, then slide the Gates cog onto the freehub with the logos and engraved part # facing outboard.

 

  • Apply RED thread-locking compound to the threads of the lockring

  • Spin the lockring onto the freehub threads, then tighten to approximately 4 Nm using a lockring wrench. (This should feel “firm” but not “tight”)

  • *Do not ride for 24 hours so the thread-locking compound has time to cure.